USP <800> Update

USP <800> Update December 2019

800 Hazardous Drugs / Physical Tests

USP Compounding Compendium

On December 1st, 2019, USP <800> went into effect.  In an effort to make sure that all our customers are completely prepared for this change, we are including the following excerpt from USP’s Frequently Asked Questions.  Please note, the information below only applies if you are a compounding facility or handle hazardous drugs.

We have highlighted questions and answers that may be of concern to you during our next certification visit. Two very important items are shown here:

USP <800> Update FAQs

 

Question 19

  • Is the C-PEC used for sterile compounding required to be exhausted to the outside or can the C-PEC be re-circulated into the negative pressure C-SEC which is exhausted to the outside of the building?
    • The Chapter requires that all C-PECs used for manipulation of sterile HDs must be externally vented. Sterile HD compounding must be performed in a C-PEC that provides an ISO Class 5 or better air quality, such as a Class II or III biological safety cabinet (BSC) or compounding aseptic containment isolator (CACI). Class II BSC types A2, B1, or B2 are acceptable. C-PECs used for pre-sterilization procedures such as weighing and mixing must be either externally vented (preferred) or have redundant–HEPA filters in series and must provide personnel and environmental protection, such as a Class I BSC or Containment Ventilated Enclosure (CVE). A Class II BSC or a CACI may also be used.
    • All hazardous drugs shall be prepared in a BSC3 or a CACI that meets or exceeds the standards for CACI in this chapter. The ISO Class 5 (reference attached) BSC or CACI shall be placed in an ISO Class 7 (reference attached) area that is physically separated (i.e., a different area from other preparation areas) and optimally has not less than 0.01-inch water column negative pressure to adjacent positive pressure ISO Class 7 (see Table 1) or better ante-areas, thus providing inward airflow to contain any airborne drug. A pressure indicator shall be installed that can be readily monitored for correct room pressurization. The BSC and CACI optimally should be 100% vented to the outside air through HEPA filtration.

Questions 32 and 33 relate to Environmental wipe sampling. Although not required by USP <800>, it is recommended to confirm containment of hazardous compounds. If you are concerned with the ability of your cabinet to contain hazardous components, Allometrics can provide you with wipe sampling kits for the analysis of possible contaminants.

To request an estimate for a preliminary visit, new compliant units or wipe Sampling Kits, you may send your inquiry to sales@allometrics.com or call us at 281-474-3329.

USP Update December 2019
USP Update December 2019
USP Update December 2019
USP Update December 2019
USP Update December 2019

Allometrics Inc.

At Allometrics, we’ve spent the last 40 years helping our customers feel confident that their measurement results are accurate and reliable.

We provide world-class ongoing calibration services to ensure you maximize the performance of your instruments throughout its lifetime.

For more information on our services and capabilities please email us at info@allometrics.com.

USP Update December 2019
You might also like:
USP 800 compliance checklist review by lab professionals in PPE

USP 800 Compliance Checklist: Hazardous Drug Requirements

Hazardous drug handling in healthcare facilities demands meticulous compliance with USP 800 standards to protect both patients and personnel from exposure risks. Whether you’re managing a hospital inpatient pharmacy, independent compounding facility, or oncology clinic, implementing USP 800 requirements…
USP 797 vs USP 800 key differences explained: pharmacist working

USP 797 vs USP 800: Key Differences Explained

Are you confident your pharmacy meets both USP 797 and USP 800 requirements—or are you unknowingly exposing your staff and patients to risk? Many pharmacy directors face confusion when trying to understand USP 797 vs USP 800 requirements. The…
USP 797 environmental monitoring technician pipetting samples onto agar plates

USP 797 Environmental Monitoring: A Complete Guide

Sterile compounding pharmacies face an ongoing challenge: proving their cleanrooms maintain the precise environmental conditions required to protect patient safety. USP 797 environmental monitoring provides the framework for this verification, but the November 2023 revisions significantly increased both the…
Preparing for a USP 797 inspection with a lab team reviewing equipment

Preparing for a USP 797 Inspection: 10 Key Steps

Regulatory inspections arrive with varying degrees of notice—sometimes scheduled weeks ahead, other times announced during a busy morning shift. Many pharmacy directors find themselves racing to gather documentation, verify staff competency records, and confirm environmental monitoring compliance before inspectors…